The low minimum detection limit and wide measurement range of the Hach 9184 sc Amperometric Free Chlorine Sensor makes it ideal for efficient residual chlorine monitoring. Continuously measures hypoch

The low minimum detection limit and wide measurement range of the Hach 9184 sc Amperometric Free Chlorine Sensor makes it ideal for efficient residual chlorine monitoring. Continuously measures hypochlorous acid (HOCl), temperature, and pH.

  • Low Minimum Detection Limit for Efficient Residual Chlorine Monitoring
  • Wide Measurement Range
  • Continuous Chlorine Measurement
  • Compatible with Hach's "Plug and Play" Digital Controllers
  • Integral temperature sensor provides more accurate readings

    Low Minimum Detection Limit for Efficient Residual Chlorine Monitoring

    The Hach 9184 sc sensor has a minimum detection limit of 5 ppb or 0.005 mg/L hypochlorous acid in the form of HOCl.

    Wide Measurement Range

    The 9184 sc sensor is particularly useful for drinking water distribution monitoring, chlorination applications, demineralizer systems, wastewater, or cooling water processes due to its 0 to 20 ppm measurement range.

    Continuous Chlorine Measurement

    Measurements are made continuously by the sensor and reported to the controller

    Compatible with Hach's "Plug and Play" Digital Controllers

    The 9184sc Analyzer is designed to be used with all Hach sc digital controllers. Set up is fast and easy, and the system is compatible with the full line of Hach digital sensors.

    Integral temperature sensor provides more accurate readings

    Hach 9184sc Chlorine sensor panel without pH sensor, 4 spare membranes, and Manual.

    Accuracy:2 % or ±10 ppb TFC, whichever is greater at pH <7.5
    Accuracy 2:2 % or ±10 ppb HOCl, whichever is greater at pH <8
    Calibration Interval:2 months
    Calibration Method:Zero Calibration: electrically (automatic) or with de-chlorinated water Calibration: Comparison of lab method with process sample pH Calibration: Single- or two-point using standards or comparison of lab method with process sample
    Enclosure Rating:NEMA 4X/IP66
    Flow:0.25 L/h (200 to 250 mL/min) auto-regulated by flow thru cell
    Interferences:No interference from chloramines. Chlorine dioxide and ozone interfere with measurement.
    Length:10.6 in ( 270 mm )
    Lower Limit of Detection (LOD):0.005 mg/L HOCl
    Maintenance Interval:6 months Measurement Cell: for membrane and electrolyte, typical
    Maintenance Interval 2:1 1.5 pH Cell: typical
    Measuring Interval:Continuous
    Measuring Principle:Amperometric/Membrane (electrode, membrane, electrolyte)
    Mounting:Flat, vertical surface (panel, stand, etc.)
    Operating Temperature Range:0 to 45 °C
    pH Range:4 to 8 acidification unit available for pH greater than 8
    Pressure Limit:0.1 to 2 bar in flow cell (1.4-28 PSI)
    Range:0 20 mg/L as hypochlorous acid (HOCl)
    Relative Humidity:0 to 90 % non-condensing
    Response Time:90 % in less than 90 seconds
    Sample Input:0.25 " outer diameter
    Sample Output:0.5 " inner diameter
    Sample Temperature:2 to 45 °C (35.6-113 F)
    Storage Conditions:-20 °C to 60 °C
    Temperature Compensation:Automatic over sample temperature range
    Warranty:2 years
    Weight:14.33 lbs. (6.5 kg) 14.3 lbs

會(huì)員登錄

請(qǐng)輸入賬號(hào)

請(qǐng)輸入密碼

=

請(qǐng)輸驗(yàn)證碼

收藏該商鋪

標(biāo)簽:
保存成功

(空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

常用:

提示

您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
在線(xiàn)留言

會(huì)員登錄

請(qǐng)輸入賬號(hào)

請(qǐng)輸入密碼

=

請(qǐng)輸驗(yàn)證碼

收藏該商鋪

該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

常用: