DeSCRJPTion
The Hardware Support Packages will permit you to configure modules that are not contained in the hardware catalog of your STEP 7 installation.
As from STEP 7 V5.2 you have the option of updating the hardware catalog via the Hardware Support Packages.
How to update the hardware catalog of your STEP 7 installation using this download is described in Entry ID: 22374877.
You obtain a list of the Hardware Support Packages contained in the download by first downloading the "STEP7_HSP.zip" file. You then unpack the Zip file and open the "HSP_Viewer.html" file contained in it with your Internet browser.

Fig. 01
You can change the language directly in the opened HSP viewer.

7-200和S7-300的以太網(wǎng)通信
S7-200 PLC本體沒有以太網(wǎng)口,需要通過以太網(wǎng)模塊CP243-1來擴展以太網(wǎng)通信,且一個S7-200PLC只能擴展一個CP243-1。CP243-1不是即插即用模塊,需要通過其他方式對S7-200下載一個包含以太網(wǎng)向?qū)У捻椖课募趴梢允褂谩?br style="margin: 0px; padding: 0px; font-family: "microsoft yahei"; list-style: none;" />通過以太網(wǎng)向?qū)?,最?個以太網(wǎng)S7控制器通信,每個連接既可以是服務(wù)器連接也可以是客戶機連接。除此之外,CP243-1還可以同時支持一個STEP 7-Micro/WIN的編程連接。
一個客戶端(Client)可以包含1-32個數(shù)據(jù)傳輸操作,一個讀寫操作最多可以傳輸212個字節(jié)。如果CP243-1作為服務(wù)器運行,每個讀操作可以傳送222個字節(jié)。
S7-200 可以通過 CP243-1 作為服務(wù)器端和客戶端建立 S7 連接,這意味著以下可能:
1. 在 S7-200 中配置一個客戶端,因此S7-200將主動激活與遠程服務(wù)器的 S7 連接。
2. 在S7-200中配置服務(wù)器連接,因此S7-200可被動的響應(yīng)建立好的S7連接,遠程的客戶端將與S7-200建立連接,S7-200作為服務(wù)器提供數(shù)據(jù)。
系列視頻:S7-200跟我學(xué)/跟我做
S7-200CN: 使用向?qū)渲每蛻魴C-跟我學(xué) - 178/185:http://www.ad.siemens.com.cn/service/elearning/cn/CourseV2.aspx?CourseID=427
S7-200CN: 使用向?qū)渲每蛻魴C-跟我做 - 179/185: http://www.ad.siemens.com.cn/service/elearning/cn/CourseV2.aspx?CourseID=428
S7-200CN: 客戶機程序的編寫-跟我學(xué) - 182/185: http://www.ad.siemens.com.cn/service/elearning/cn/CourseV2.aspx?CourseID=431
S7-200CN: 客戶機程序的編寫-跟我做 - 183/185: http://www.ad.siemens.com.cn/service/elearning/cn/CourseV2.aspx?CourseID=432
S7-200作為客戶機
可以把S7-200的以太網(wǎng)模塊CP243-1配置為CLIENT,使用STEP 7 Micro/WIN中的向?qū)нM行通信的配置即可。在命令菜單中選擇工具--以太網(wǎng)向?qū)А?/p>

圖1 打開以太網(wǎng)向?qū)?nbsp;
第一步是對以太網(wǎng)通信的描述,點擊下一步開始以太網(wǎng)配置。

圖2 向?qū)Ы榻B
在此處選擇模塊的位置,CPU后的第一個模塊位置為0,往后依次類推;或者在線的情況下,點擊讀取模塊搜尋CP243-1模塊(在線讀取將該模塊的命令字節(jié)載入模塊命令字節(jié)向?qū)聊唬?。點擊下一步;

圖3 讀取模塊
選擇模塊相匹配的MLFB版本,本例中的CP243-1模塊型號為6GK7243-1EX01-0XE0,如下圖所示:

圖4 模塊版本選擇
在此處填寫IP地址和子網(wǎng)掩碼。點擊下一步;

圖5 地址設(shè)置
下面的對話框?qū)⒔M態(tài)CP243-1進行S7連接的連接數(shù)量的設(shè)置,通過S7連接可以與通信伙伴進行讀寫數(shù)據(jù)操作。點擊“下一步”按鈕繼續(xù)進行S7連接組態(tài)。

圖6 模塊占用地址設(shè)置
選擇此為客戶機連接,遠程屬性TSAP (Transport Service Access Point)填寫為03.02,輸入S7-300側(cè)的IP地址。點擊數(shù)據(jù)傳輸按鈕進入數(shù)據(jù)交換的定義。
注意:如果連接遠程對象是 S7-300,TSAP為03.02;如果連接遠程對象是 S7-400,TSAP為03.0x,其中x為CPU模塊的槽位,可以從S7-400 站的硬件組態(tài)中找出PLC的槽號。

圖7 連接設(shè)置
選擇"數(shù)據(jù)傳輸"標記,并單擊"新傳輸"按鈕,進行配置:選擇是讀取數(shù)據(jù)還是寫入數(shù)據(jù),填寫通訊數(shù)據(jù)的字節(jié)個數(shù),填寫發(fā)送數(shù)據(jù)區(qū)和接收數(shù)據(jù)區(qū)的起始地址。
本例中為從S7-300的MB200開始讀取8個字節(jié)到VB1000開始的8個字節(jié)的區(qū)域中;從S7-200的VB2000開始的8個字節(jié)寫到S7-300的QB0開始的8個字節(jié)的區(qū)域中,點擊確認按鈕:
注意: 本地PLC中的地址必須是V內(nèi)存字節(jié)地址,遠程對象中的地址必須代表字節(jié)地址。當(dāng)您為S7-300/ S7-400設(shè)備輸入遠程地址時,若是數(shù)據(jù)塊請使用DBx.DBBy格式。


圖8 數(shù)據(jù)區(qū)域設(shè)置
選擇CRC校驗,使用缺省的時間間隔30秒,點擊下一步按鈕。

圖9 使用CRC
填寫模塊所占用的V存儲區(qū)的起始地址。你也可以通過“建議地址”按鈕來獲得系統(tǒng)建議的V存儲區(qū)的起始地址, 點擊下一步按鈕。

圖10 配置存儲區(qū)